The pumps consist of three main assemblies:
n
Housing with driver unit
n
Pump head
n
Control unit.
The construction has been chosen in such a way that it is very easy to switch between the
'EcoPro' and 'EcoAdd' control units (
'EcoAdd' ' on page 78). The control units can also be rotated variably on the housing
Ä Chapter 11.2.1 'Conversion- Rotating the control unit' on page 77).
(
On the supplied mounting plate, the pump can be used without tools both for stand
mounting and wall mounting (
CAUTION!
The use of a suction pipe with an empty signal provision and dirt trap from
our accessory programme is highly recommended to protect the metering
system. The empty signal system causes the pump to cut off if the medium
in the container drops below a certain level.
4.1

Features - 'EcoPro'

n
Buttons: On/Off, Test
Viscosity: high/low
n
n
Setting range: 1:100
n
LEDs: Operation, viscosity high/low, alarm
n
Connection board with connection points for:
– Power supply
– Enable signal
Ä Chapter 11.2.2 'Upgrade - from 'EcoPro' to
Ä Chapter 6.2 'Assembly variants' on page 33).