6.2.2

Wall mounting

Fig. 8: Preparations for wall mounting
For wall mounting, retaining elements (supplied) with the marking 1 (Fig. 8,
Pos. 2) and the element with the marking 2 (Fig. 8, Pos. 3) will be used.
1.
Turn the mounting plate over.
2.
Put holding elements (key figure: 1, Fig. 8 , pos. 2) from behind into the two upper
openings marked "wall" (= wall mounting)and engage into position.
3.
Put holding elements (key figure: 2, Fig. 8, pos. 3 ) from behind into the two lower
openings marked "wall" and engage into position.
4.
Turn the mounting plate over again and hold it against the required mounting
position.
5.
Using mounting plate as a template, mark the required boreholes with a sharp pencil
(Fig. 8, Pos. 5).
6.
Make the holes.
7.
Fasten the mounting plate securely to the wall.
8.
Place the pump onto the hooks on the mounting plate from above.
9.
Slide the pump downwards onto the mounting plate until it engages with an audible
click.
10.
11. Attach the connecting lines (hydraulic and electric):
Ä Chapter 6.3.1 'Hydraulic Installation' on page 36
Ä Chapter 6.4 'Electrical installation' on page 45.
1
The hooks of the fastening elements must point upwards.
By pressing down the retaining tab (Fig. 8, pos. 6) the pump can be
removed from the mounting plate.
Mounting and installation
2
5
5