Replacement Of Diaphragm And Pump Head - Ecolab EcoPro Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Servicing
9.6

Replacement of diaphragm and pump head

Personnel:
Protective equipment:
CAUTION!
Diaphragms:
– Before changing the diaphragm, it is essential to change the pump
modus to the Service position!
on page 58
– Only tighten diaphragms by hand and do not use any tools!
The service life of the diaphragm depends on the following:
– back pressure
– operating temperature
– and metering medium
We recommend that you check the diaphragm more frequently in extreme
operating conditions and if metering abrasive substances.
NOTICE!
It is essential that the tightening torques given below are observed, firstly to
ensure the leak-tightness of the system and secondly to ensure the integrity
of the thread.
The tightening torques of the metering head screws are given on an
adhesive label that is affixed to the pump head.
Tightening torque of the metering head screws:
Pump head size
Tightening torque
417102264 Rev. 6-12.2019
n
Mechanic
n
Service personnel
n
Specialist
n
Chemical-resistant protective gloves
n
Protective eyewear
n
Safety shoes
Ä Chapter 9.1 'Service position'
5 l/h and 11 l/h
3,75 ± 0.25 Nm
62
5 l/h and 11 l/h
6 ± 0.25 Nm
5 l/h and 11 l/h
6 ± 0.25 Nm

Publicité

Table des Matières
loading

Table des Matières