Operation

9.1

Operating mode

By pressing the up and down buttons ( and ) simultaneously, you can toggle between
internal and external 4 - 20 mA operating modes, and the corresponding LED
(see chapter 5.2, pos.
9.1.1

Internal operating mode

If 'internal' operating mode is set ("internal" LED is illuminated, see chapter
pump runs at the configured metering frequency after the metering lock (release) contact is
closed (see chapter 7.2.3.1). The selected setting appears on the display as a % of the max.
metering frequency or capacity (see chapter
The active metering frequency while the pump is running is represented by an on/off interval
on the metering mode / operating state / metering stroke indicator LED (see chapter 5.2, pos.
5, 6, 7) (metering stroke = on, suction stroke = off).
9.1.1.1 Metering frequency setting (metering quantity)
By pressing the up button  or the down button , the % shown on the display changes
accordingly (setting range: 1 - 100 %).
The adjustment can also be made while the pump is running, whereby the metering
frequency follows the altered value immediately (there is no need to save the new value).
IMPORTANT
9.1.2
External 4 – 20 mA operating mode
If 'external 4-20 mA' operating mode is selected ("4-20 mA" LED is illuminated,
(see chapter 5.2, pos. 4) the pump runs at a metering frequency of between 0 and 100 %
(4 – 20 mA = 0 – 100 %) after the metering lock (release) contact is closed
(see chapter 7.2.3.1) depending on the level of the current signal created
(see chapter 7.2.3.2).
The active metering frequency is represented, on the one hand, as a % on the display and,
on the other hand, by an on/off interval on the metering mode / operating state / metering
stroke indicator LED (see chapter 5.2, pos. 5, 6, 7) (metering stroke = on, suction stroke =
off).
9.2

Test function

While the TEST button is pressed in, the pump runs at a metering frequency of 100 % in the
default metering mode (see chapter 9.3).
417102213_EDP L_V15.docx
3
& 4) is illuminated.
In order to obtain precise details of the metering quantity currently configured, the
pump capacity has to be gauged after every metering quantity adjustment
(see chapter
8.3
Determining the metering quantity).
5.2
pos. 1).
- 48 -
5.2
pos. 3), the
Rev. 1.10.11