10.3

Gear oil change

The safety regulations of the German Water Resources Law (WHG), as well as all
CAUTION
instructions given in the product specification sheet of the gear oil have to be observed.
Wear appropriate protective clothing.
Fig. 10.5
Gear oil top up:
 Fill new gear oil into the aperture for the gear bleeder screw (pos. 1) using an
appropriate funnel (filling volume approx. 0.8 l).
 Check the oil level on oil-level gauge glass (pos. 2); (min. and max. oil level, see Fig.
10.6, and rectify if necessary.
The gear oil used here is a polyglycol oil of type Klübersynth GH6-320. Only this gear oil
or a polyglycol oil of an identical specification (conforming to DIN ISO 6743) may be used.
NOTE
417102213_EDP L_V15.docx
Item
Description
1
Gear bleeder screw
2
Oil-level gauge glass
3
Sealing plug
NOTE
Draining gear oil:
 Remove the gear bleeder screw (pos. 1).
 Place a suitable collecting basin (min. 0.9 l)
underneath the sealing plug (pos. 3).
 Unscrew the sealing plug carefully.
 As oil runs out, catch it in a receptacle.
 Screw in the sealing plug with a new O-ring
(NBR
9 x 2 mm) and tighten it.
Used gear oil must be disposed of correctly!
- 52 -
Before changing the oil, the pump
has to be put into operation in order
to achieve a minimum temperature
of approx. 30°C.