Fit the dongle- box or the MicroFlow- Box (Fig. 8.1) to the rails of the EMP pump provided for
this purpose (Fig. 8.2, Pos. A):
Slide the dongle box (Fig. 8.1) onto the rail on the left side of the EMP pump
(Fig. 8.2, Pos. A), until it snaps into place.
Connect the connection cable (Fig. 8.1, Pos.
standard signal (Fig. 8.2, Pos. 1).
Switch the pump off and afresh on.
The additional functions in the metering pump electronics can thus be activated and
executed.
If, before upgrading with a dongle box or a MicroFlow-box, a plug is connected to the input
NOTE
for pulse / standard signal (see Fig. 8.2, Pos. 1), then this plug can be connected after the
upgrade to plug VIII (see Fig. 8.1, Pos. VIII) of the dongle box or Microflow-box.
8.2
Connector assignments of the slots
8.2.1
Connector assignments of slot V (5-terminal),
Remove the protective cap
Mount the connector plug according to the connector assignment.
WARNING
Only use a connector plug from our product range!
8.2.1.1
Installing the oval gear meter
8.2.2
Connector assignments of Slot V, MicroFlow- Box
417101438_EMP_II_E60
Conductor coloring
Pin
(cable connection)
1
brown
2
white
3
blue
4
black
5
grey
Fig. 8.4
Connector assignments of slot V (5-terminal), input for Dongle-box
OGM
Conductor coloring
Pin
(cable connection)
1
2
3
blue
4
black
5
Fig. 8.6
Connector assignments of slot V (5-terminal), MicroFlow-Box
3
and 8.3, Pos. 2) to the input for pulse /
Dongle-box
Assignment
Supply for oval gear meter 5 V DC (load with max. 50 mA)
Bus line for oval gear meter, type OGM
Switch input
GND (┴)
Free for future use
PLUS
1
+
2
+ 3+
PIN
1
2
3
4
Fig. 8.5
Installing the oval gear meter OGM
Assignment
not occupied
not occupied
Signal input MicroFlow- Transducer
GND ( ┴ )
not occupied
- 93 -
PLUS
4
= OGM
PLUS
Assignment
5 V
Bus signal
Relay input
GND (┴)
PLUS
Rev. 12-01.19