10.3.14.1 Selecting

Fig. 10.40 Configuration MicroFlow
10.3.14.2 MicroFlow
Fig. 10.41 Configuration MicroFlow
10.3.14.3 MicroFlow
417101438_EMP_II_E60
PLUS
: Selecting
PLUS
/ Stop pump
PLUS
/ Stop pump
PLUS
/ Strokes
-
MicroFlow
(Default setting)
MicroFlow
On activating
submenu appears with the following
menu items:
Menu item
• Stop pump
• Strokes
• Deviation
• Metering break
• Metering delay
Calibration
The "stop pump" function is used
to set whether or not the pump
stops if a "metering monitoring
alarm" is triggered.
-
Pump is not stopped in the
event of an „Alarm metering
monitor function"
(Default setting)
Pump is stopped in the event
of an „Alarm metering monitor
function"
Fig. 10.42 Configuration MicroFlow
The "Strokes" option is used to
specify the interval of strokes to
be monitored.
Setting range: 0-100
Default setting = 10 strokes
- 114 -