Calibration / Manual

If the calibration value to be entered is known, a "dry calibration" (immediate entry of the
value without a previous calibration process) can be conducted.
However, this method is not very accurate as no consideration is given to the on-site
conditions (back-pressure, viscosity, cable cross-sections and lengths etc).
Fig. 10.60 Calibration / Manual
10.4.4.1

Calibration data table

The pump capacity in l/h is allocated to the pump's electronics on the basis of the calibration
values entered in the table.
Example: A specified value of 23.3 ml results in a pump capacity of 1.4 l/h.
NOTE
These values relate to the metering medium of water at 20°C
Fig. 10.61 Calibration data table
10.5

Operating data

The following operating data is recorded and displayed under this menu item:
Operating hours
Liter
Amount of pulses
417101438_EMP_II_E60
Pump
Pump capacity [l/h]
at 50 (60) Hz
1,4 (1,7)
2,5 (3,0)
4,3 (5,1)
4,8 (5,7)
7,2 (8,6)
11,2 (13,0)
24,0 (29,0)
- 122 -
Pump calibration value [ml]
at 50 (60) Hz
23,3 (28,3)
41,6 (50,0)
71,6 (85,0)
80,0 (95,0)
120 (143)
187 (217)
400 (483)
Rev. 12-01.19