Calibration / Start; Calibration / Manual - Ecolab Elados EDPL V60 Notice Technique

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

10.5.3.2 Calibration / Start

Fig. 10.53
Re. :
The pump is running for 60 s. (The seconds count down from 60 to 0).
The oval gear meter pulses (OGM pulses) are counted up from 0.
The calibration can be interrupted by actuating the 'Menu/Exit' function.
NOTE
If the OGM pulses are not displayed, check all the connections to the pump!
Re. :
After the running process, the quantity removed from the measuring cylinder (see
chapter
This quantity is then entered as the calibration value (in ml or l).
10.5.4

Calibration / Manual

If the calibration value to be entered is known, a "dry calibration" (immediate entry of the
value without a previous calibration process) can be conducted.
However, this method is not very accurate as no consideration is given to the local conditions
(back-pressure, viscosity, cable cross-chapters and lengths etc).
Fig. 10.55
417102214_EDPL_V60.docx
10.5.3.1
"Preparation") must be read off.
Fig. 10.54
During the calibration process, the oval gear pulses (21432)
determined appear on the display.
102
Rev. 1.12.11