Installation

• The metering pump should be mounted at an easily accessible, frost-protected location.
• The ambient temperature must not exceed +40°C.
• The device must be installed in a horizontal position.
• The pump is to be screwed securely to the bracket or the container at the drill holes
provided (for information on the drill hole gap, see chapter
In accordance with DIN EN 809 5.2.1.4, please be advised that if the pump is not screwed
securely to the base (for example, during transport, installation or dismantling), it may lose
its stability if tilted at an angle of 10° or more in any direction.
ATTENTION
If the pump is not securely screwed to its base, appropriate safeguards must be put in
place to protect it against toppling over.
6.1

Installation scheme

Fig. 6.1
Metering/pressure-control and over-pressure valves may be replaced by a multi-function
NOTE
valve (MFV) from our range which combines all these functions.
417102214_EDPL_V60.docx
14.2
Pos.
Description
1
Overflow valve
2
Metering valve / Injection valve
Alternatively:
3
Multi-function valve
4
Suction pipe or floor suction valve
70
"Dimensions").
Rev. 1.12.11