10.3.2.2 Display value in the operating level / Setting

The metering quantity can be configured/adjusted in the operating level during operations.
The original value is retained if the newly set value is not confirmed within 10 seconds by
NOTE
pressing the START/STOP button.
Fig. 10.7
Fig. 10.9
10.3.3

Operating mode / Pulse

In "Pulse" operating mode, the pump meters a defined quantity in proportion to an incoming
pulse rate (for example, from a contact water meter). The pulse interval (ml, l / pulse) for the
flow meter being used must be entered here first of all.
The required concentration in % or the metering quantity per pulse [ml/p] can then be
selected in the operating level.
The pump software independently calculates the necessary metering stroke speed or
metering quantity from these parameters and sets the pump accordingly.

10.3.3.1 Selection

Fig. 10.11
417102214_EDPL_V60.docx
Strokes/min
Litres
Per cent (%)
Fig. 10.8
Fig. 10.10
87
Gallons
Setting range:
10 ml – 100 l / pulse
Rev. 1.12.11