Configuration / Unit

If 'litre' is selected for the 'Internal' operation mode (see chapter
the operating level / Setting"), this can be used to change the display from litres / h to gallons
/ h or gallons / day (1 gallon = 3.785 litres).

10.4.4.1 Selection

10.4.5

Configuration / Max. output

The maximum metering capacity of the pump can be limited here.
The value is entered as a percentage and can be set at intervals of 10 between 100 % and
30 %. A setting of 80 %, for example, means that the maximum value for the metering
frequency (metering quantity setting of 100 % in 'Internal' operating mode or a current input
of 20 mA in 'Current' operating mode) only reaches 80 % of the maximum possible metering
frequency.
Example:
Max. power setting = 100 %
metering mode:
Max. possible metering frequency [1/min]:
Max. possible metering quantity in l/h:
After every adjustment under the 'Metering capacity' menu option, the pump must be re-
calibrated! Therefore, the icon "c!" appears in the operating level display.
IMPORTANT
Once automatic calibration has been correctly performed, the icon "
10.4.5.1 Selection
417102214_EDPL_V60.docx
Pump type 02200 (220 l/h),
calibrated with water at 20 °C,
short suction and pressure lines
standard [s]
Fig. 10.23
Default setting: Litres
medium [m] low [l] standard [s] medium [m] low [l]
120
100
80
220
183
147
Fig. 10.24
Setting range:
92
10.3.2.2
"Display value in
Max. power setting = 80 %
96
80
176
149
" then appears!
100% – 30%
(in 10 % intervals)
Rev. 1.12.11
64
122