Metering Quantity / Pulse Setting In The Operating Level; Metering Quantity / Pulse Display During Operation; Operating Mode / Current (External Standard Signal) - Ecolab Elados EDPL V60 Notice Technique

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

10.3.3.5 Metering quantity / pulse setting in the operating level

If the pulse interval setting is = 0 (see chapter
metering quantity / pulse [ml / pulse] is configured / adjusted in the operating level. This can
also be done while the system is in operation.

10.3.3.6 Metering quantity / pulse display during operation

Fig. 10.16
10.3.4

Operating mode / Current (External standard signal)

In the "current" operating mode, the pump functions on the basis of an incoming standard
signal. The incoming signal (0/4 - 20 mA; 20 - 0/4 mA or variable) is converted into a
metering frequency of 0-100 %.
The following operating options can be selected:
• 0 – 20 mA
• 4 – 20mA
• 20 – 0 mA
• 20 – 4 mA
• variable
417102214_EDPL_V60.docx
Fig. 10.15
Pulse interval setting ≠ 0
(see chapter 10.3.3.2) „Setting the pulse interval")
Pos. Description
1
2
3
4
0 mA = 0% metering frequency, 20 mA = 100 % metering frequency
4 mA = 0% metering frequency, 20 mA = 100 % metering frequency
20 mA = 0% metering frequency, 0 mA = 100 % metering frequency
20 mA = 0% metering frequency, 4 mA = 100 % metering frequency
n (variable) mA = 0 % metering frequency,
n (variable) mA = 100 % metering frequency
10.3.3.2
"Setting the pulse interval") the
Operating mode
metering quantity currently being processed [µl, ml, l]
(increases with every incoming pulse, decreases with
every processed metering stroke)
Configured metering quantity per pulse [ml / p.]
Active metering capacity in %
89
Rev. 1.12.11

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Elados edpl v60plus418463204249629

Table des Matières