Setting The Metering Capacity (Mechanical) - Ecolab Elados EMP III - E00 Manuel D'utilisation

Pompe doseuse à membrane
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Startup
6.2

Setting the metering capacity (mechanical)

Fig. 6: Setting the dosing capacity
1
locking screw
The metering capacity is adjustable by means of mechanical stroke length setting
between 100 % and 30 % of the pump's rated capacity (reproducible accuracy can no
longer be guaranteed below 30 %).
1.
In order to be able to adjust the dosing capacity, the locking screw (pos. 1) must first
be loosened by approx. one turn.
2.
The adjustment is carried out via the stroke adjustment knob (pos. 2) and can only
be carried out during operation of the dosing pump.
After setting metering capacity tighten locking screw.
The pump capacity has to be measured in order to determine the metering
capacity accurately (
measurement)' on page 40).
417102233 Rev. 3-03.2019
2
stroke adjustment knob
Ä Chapter 6.4 'Metering capacity calculation (volumetric
38

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Elados emp iii - e10

Table des Matières