General Data - Standard Pumps; Deviant Datas - Pumps In The "Higher Pressures (Hp)" Versions - Ecolab Elados EMP III - E00 Manuel D'utilisation

Pompe doseuse à membrane
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

10.3
General data – Standard pumps
Description
Pump output [l/h]*/**
Max. metering backpressure [MPa (bar)]**
Max. permissible pre-pressure [bar]
Number of strokes [1/min] at 50 Hz
Metering quantity/stroke [cm³]
Metering accuracy [
capacity depending on the backpressure and stroke
setting' on page 60]
Max. conveyable viscosity [mPas]
Permitted ambient temperature
Suction height [mWs] at 100 % stroke***
Noise level (DBA) in 1 m distance
(according to DIN EN 12639/ EN ISO 9614-2)
Max. pre-pressure (suction side) [MPa (bar)]
Recommended minimum diameter of suction/
pressure connector [ID mm]
Weight [kg]
* All data relate to water at 20 °C.
** At mains power frequency 60 Hz, the delivery capacity increases by 20 %, while metering backpressure decreases 20 %.
*** Suction heights with clean, moistened valves at 100 % metering stroke and max. stroke frequency.
DANGER!
With reference to DIN EN 809 5.2.3, please be advised that the surface
temperature of the motor may exceed 80°C under certain circumstances.
Therefore, ensure that this area cannot be touched during operation!
10.3.1
Deviant datas – Pumps in the "Higher Pressures (HP)" versions
Description
Pump output [l/h]*
Max. metering backpressure [[MPa (bar)]
Metering quantity/stroke [cm³]
* all data relate to water at 20 °C.
Ä Chapter 10.9 'Delivery
Pump
Pump
type
type
00160
00250
16
25
1 (10)
0,8
122
2,1
3,4
6 mm PVC tube
6/12, 10/16
7,4
Pump type 00160
14,7
1,6 (16)
1,98
55
Technical data
Pump
Pump
Pump
type
type
type
00540
00800
01200
54
80
120
0,4 (4)
0,3 (3)
0,6
7,3
10,8
16,1
< ± 3%
200
5-40 °C
0,05 (0,5)
48,0
0,5
12 mm PVC tube
12/21
8,6
Pump type 00250
23,5
1,2 (12)
3,15
417102233 Rev. 3-03.2019