General Data - Ecolab Elados EDPL V15 Notice Technique

Pompe doseuse à membrane
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

13.3.2

General data

Description
Pump output [l/h]* in metering mode:
Metering back-pressure [MPa (bar)]
Number of strokes [1/min] in metering mode:
Metering quantity/stroke [ml]
Reproduction accuracy (see chapter 13.7)
max. conveyable viscosity [mPas]
Permissible ambient temperature
Suction height [mWS] at 100 % stroke
max. suction-side pre-pressure [MPa (bar)]
noise level (DBA) at a distance of 1m
(acc. to DIN EN 12639/ EN ISO 9614-2)
Recommended minimum diameters:
Weight [kg]
*
Values determined with water as the metering medium at a temperature of 20°C.
**
Suction heights determined with clean, moistened valves at max. stroke frequency
ATTENTION
13.3.3
Input/output wiring (also see chapter 7.2.3)
13.3.3.1 Slot I
Fig. 13.2
Inputs
Metering lock
(release) with a floating
contact
Metering lock (release)
with an electronic
switch
Metering lock (release)
with external voltage
Standard signal
417102213_EDP L_V15.docx
high / low
medium / medium
low / high
high / low
medium / medium
low / high
setting**
Suction connection [ID mm]
Pressure connection [ID mm]
With reference to DIN EN 809 5.2.3, please be advised that the surface temperature of
the motor and frequency convertor may exceed 80°C under certain circumstances.
Therefore, ensure that these areas cannot be touched during operation!
Assignment
bridge 1 (br) + 2 (wh)
3 (bl) + 4 (bk)
= floating contact
NPN
bridge 1 (br) + 2 (wh)
2 (wh) + 3 (bl) + 4 (bk)
= elect. switch
PNP
1 (br) + 2 (wh) + 3 (bl)
= elect. switch
bridge 3 (bl) + 4 (bk)
2 (wh) + 3 (bl)
5 (gr) + 4 (bk)
Pump type
02200
04800
220
480
183
400
147
320
1,0 (10)
0,6 (6)
120
100
80
30,6
66,7
< ± 3%
600 mPas
5-40°C
2
0,2 (2)
66,0
DN 20
DN 25
DN 12
DN 20
26,7
28,5
External wiring
Floating contact
Attention: Do not
connect any
external voltage!
Electronic switch
Attention: Do not
connect any
external voltage!
External voltage
External current
Attention:
Check polarity!
- 61 -
06700
670
558
447
0,4 (4)
93,1
DN 30
DN 25
30
Values
min. on/off time =
15 ms
4....30 V DC
0/4-20 mA, load
approx. 50 ohms
Rev. 1.10.11