Calibration / Manual

If the calibration value to be entered is known, a "dry calibration" (immediate entry of the
value without a previous calibration process) can be conducted.
However, this method is not very accurate as no consideration is given to the on-site
conditions (back-pressure, viscosity, cable cross-chapters and lengths etc).
Fig. 10.48

10.4.4.1 Calibration data table

The pump capacity in l/h is allocated to the pump's electronics on the basis of the calibration
values entered in the table.
Example:
A specified value of 2.33 l results in a pump capacity of 140 l/h.
NOTE
These values relate to the metering medium of water at 20°C
Pumpe
10.5

Operating data

The following operating data is recorded and displayed under this menu item:
Operating hours
Liter
Amount of plulses
417101799_EMP_IV_E60.docx
Pump capacity [l/h]
at 50 (60) Hz
Fig. 10.49
140 (168)
210 (252)
450 (540)
630 (756)
750 (900)
Pump calibration value [l]
at 50 (60) Hz
2,33 (2,80)
3,50 (4,20)
7,50 (9,00)
10,5 (12,6)
12,5 (15,0)
- 105 -
Rev. 9-06.11