10.3.11.1 Selecting
10.3.12 Configuration / Metering controller (only E60
Fig. 10.28
If an OGM Plus is connected, when the metering controller function is activated, the dosage
quantity measured by the OGM is compared with a pre-defined dosage quantity target
value. If there is a discrepancy between the values, the metering frequency of the pump is
automatically increased or decreased.
Since metering frequency can only be adjusted within the performance limitations of the
pump, setting the dosage quantities higher than 80 or 90% of the maximum possible
metering frequency is not recommended. This will ensure that the metering controller retains
sufficient reserves to react to negative control deviations.
The metering controller function can only be used in the 'internal' and 'current' operating
modes. If the operating mode 'pulse' is selected, the metering controller function will not
work.
The metering controller function can only be activated if the pump is upgraded with a
dongle plate
connected.
NOTE
To activate the dongle plate in connection with the oval gear meter, the power supply has
to be switched off and on again!
10.3.12.1 Selecting
417101799_EMP_IV_E60.docx
PLUS
to the
E60
and oval gear meter , type OGM
- 98 -
Fig. 10.27
-
oval gear meter is inactive.
(Default setting)
oval gear meter is active.
PLUS
PLUS
& OGM
)
PLUS
(see Accessories) is
Fig. 10.29
-
controller function is inactive.
(Default setting)
controller function is active.
Rev. 9-06.11