9.4

Description of display symbols

Display
Intern
MUL
DIV
x..xx mA
Charge
xxx /min
xx %
x.xx l/h
n =
x
xx.x mA
f = xx.x %
OFF
E60+
E60++
Alarm
9.5

Initial startup / Delivery status

Fig 9.7
In the as-delivered condition, the pump is configured as follows.
Operating mode: Internal
Status:
To change the preconfigured factory settings, observe the corresponding menu items in
NOTE
Chapter
417101799_EMP_IV_E60.docx
Description
Pump's operation mode: the top right indicator in the display
stroke.
Level report is active (flashing display = low level advance warning, display is permanently
visible = empty report), see
warning and empty report or
Metering lock active, see
7.2.4.4
Configuration / Metering lock
Fault report, see
12.2
Alarm messages
Operation mode internal, see
Operation mode pulse multiplication, see
Operation mode pulse division, see
Operation mode current x – xx mA, see
Operation mode batch see
Display strokes / min at Operation mode internal
Display % at Operation mode internal
Display l/h at Operation mode internal; see
Display at operation mode pulse, see
Display at operation mode current, see
Display of the current metering frequency in %
Pump is in operating state OFF (must be switched on), see
Dongle box is connected, see
PLUS
Dongle box and OGM
Configuration / Oval gear meter
Alarm operation mode, see
Stroke frequency:
pump in the "OFF" ("Standby" in V 3.5)" operating state
10.3
"Configuration".
7.2.4.1.1
Installing the suction pipe with low-level ad advance
10.3.8
Configuration / Low-level contact
Installing the control via the metering lock or
10.2.2
Operation mode / internal
10.2.3
Operation mode / pulse
10.2.3
Operation mode / pulse
10.2.4
Operation mode / current
10.3.14
Configuration / Batch
10.2.2.2
Display / setting operation mode internal
10.2.3.2
Display / setting operation mode pulse
10.2.4.2
Display / operation mode current
8
Upgrading to Version Chem-Ad
are connected, see
8.1.2
Installing the oval gear meter or
12.2
Alarm messages
In delivery condition, the pump is protected against
escape of gearbox oil by means of a sealing
closure on the oil filler opening.
WARNING
50 Hz
< 750 l/h = 122 strokes/min
≥ 750 l/h = 146 strokes /min
50 Hz
60 Hz
< 900 l/h = 146 strokes /min
≥ 900 l/h = 176 strokes /min
60 Hz
- 86 -
makes a full rotation with each
10.3.7
9.5.2
Display at operating display
®
Plus
Serie B E60
10.3.11
Before start-up the pump:
Replace the locking screw on
the oil charging hole with the
enclosed vent screw
Rev. 9-06.11