Configuration / Autostart

This function determines whether the pump is set to 'OFF' ('Standby' in V 3.5) when the
mains connection is re-established following a power cut or if the pump should immediately
recommence functioning in the configured operation mode.
10.3.6.1 Selecting
10.3.7

Configuration / Metering lock

If the metering lock is enabled, the pump only functions if an external enable contact is
connected to plug II between PINS 3+4 (see chapter 7.2.4.4) (regardless of which operation
mode is set).
417101799_EMP_IV_E60.docx
Fig. 10.18
- Code query inactive.
(Default setting)
 Code query active.
see chapter
Fig. 10.19
Fig. 10.20
-
autostart ist inactive.
When the mains voltage is applied,
the pump always enters the "OFF"
("Standby" in V 3.5) operating state.
(Default setting)
autostart ist active.
When the mains voltage is
connected, the pump starts
functioning in the configured
operation state.
- 95 -
10.3.5.2
Rev. 9-06.11