10.3.7.1 Selecting
10.3.8
Configuration / Low-level contact
This function specifies whether an open or a closed contact at the level input (plug I, see
chapter 7.2.4.1) is regarded as level OK.
10.3.8.1 Selecting
10.3.9
Configuration / Alarm output
This option permits the inversion of the alarm output (alarm output relay has pulled in or not
pulled in when the alarm was triggered).
10.3.9.1 Selecting
417101799_EMP_IV_E60.docx
Fig. 10.21
-
interrogation of the metering lock
is inactive. (Default setting)
interrogation of the metering lock
is active.
Fig. 10.22
= contact open:
level not OK (empty)
contact closed:
level OK (full)
(Default setting)
=
contact closed:
level not OK (empty)
contact open:
level OK (full)
Fig. 10.23
= When an alarm is triggered, the
relay is pulled in for the alarm
output.
(Default setting)
= When an alarm is triggered, the
relay is not pulled in for the alarm
output.
In addition to the function mode of the
relay, it is also possible to select
whether the alarm output relay contact
is closed (closing function on, default
setting) when the relay is pulled in or
open (opening function) (see chapter
7.2.8
Hardware changeover alarm
signal.
- 96 -
Rev. 9-06.11