Installation diaphragm burst detector
7.2.5.1
Fig.7.27
Installation metering monitoring
7.2.5.2
The metering monitoring funktion must be activated in menue first.
NOTE
(see chapter:
Fig. 7.28
7.2.6
Connector Assignments Terminal X3
Fig. 7.29
Installation low-level warning and fault
7.2.6.1
Fig. 7.30
417101799_EMP_IV_E60.docx
13+14+15+16
Terminal Conductor
13
14
15
16
10.3.13
metering monitoring configuration)
Terminal
Description
1
Out put low-level advance warning, empty report, fault report
2
- 82 -
= Input diaphragm burst detector
Assignment
coloring
(cable
connection)
brown
Anode for sensors with anode
terminal
white
Output 5V DC
blue
Relay input diaphragm burst signal
black
GND
20
+
21 =
monitoring with potential-free
contact
Terminal Assignment
Relay input metering
20
monitoring
GND ( ┴ )
21
19
+
20
+
21
monitoring function with electronic
switch
Terminal Assignment
19
Output 5V DC
Relay input metering
20
monitoring
GND ( ┴ )
21
1
+
2
=
Output low-level warning, empty
report and fault
Input low-level warning active:
relay output connected
Input low-level warning active acc. fault
container active:
relay output closed (function invertible see chapter,
7.2.8
ecc.
10.3.9)
relay output = potential-free relay contact,
load 24 V AC/DC 3 A ecc. 115/230V 3A
Input metering
= Input metering
Rev. 9-06.11