Device installation
7.2.4

Connector assignments of slot III (4-terminal) Output for alarm and stroke signal

Fig. 18: Slot III (4-terminal))
Conductor
PIN
coloring
1
brown
2
white
3
blue
4
black
plug assignment
1.
Remove the protective cap.
2.
Mount the connector plug according to the connector assignment.
CAUTION!
Only use a connector plug from our product range! (included in the delivery
scope).
7.2.4.1 Installing the alarm or fault report output at 24 V
Fig. 19: Installing the alarm or fault report output at 24 V
1
Relay output
1 + 2 = Output low-level warning, empty report and fault
Input low-level warning active:
relay output connected.
Input low-level warning active acc. fault container active:
relay output closed (function invertible
Ä Chapter 7.2.4.3 'Hardware migration for alarm contact' on page 45),
on page 77 (
relay output = potential-free relay contact, load 24 V AC/DC 3 A ecc. 115/230V 3A.
WARNING!
At 115V/230 V, a simultaneous connection of contact 1+2 (alarm output) and
3+4 (stroke signal output) is generally not permitted.
417101442 Rev. 12-02.2019
Assignment
Output low-level warning, empty report and fault (+)
Output low-level warning, empty report and fault (-)
Output stroke signal (+)
Output stroke signal (-)
Ä Chapter 14.5.3 'Connector III' on page 126.
Ä Chapter 10.3.9 'Configuration / Alarm output'