Menu description
10.3.14.6 MicroFlow
PLUS
Use the "Metering delay" option to specify the time during which the metering monitoring
function is disabled when handling out gassing media to allow time for degassing the
system.
Once the metering pause time has expired, the "Metering delay" is activated as soon as
the next metering is initiated
(
Ä Chapter 10.3.14.5 'MicroFlow
Fig. 69: Configuration MicroFlow
Example:
Metering pause = 240 s,
Metering delay = 40 s,
This example has a metering pause of 240 seconds during which metering is stopped.
The metering delay of 40 seconds is initiated with the next metering request during which
the metering monitoring of the MicroFlow
Any gas bubbles can be removed from the system without triggering an alarm during this
time.
Setting range: 2 - 3600 s
Default setting = 40 sec.
417101442 Rev. 12-02.2019
/ Metering delay
PLUS
PLUS
/ Metering delay
/ Metering break' on page 91).
PLUS
is interrupted.
92