7.1.2

Connecting the suction line and return line

Fig. 9: Connecting the suction line and return line
1
Union nut
2
Clamping piece
3
Connection piece
n
Separate double-hose, cut it straight and remove the connecting bridge.
n
Push union nut (pos. 1) and clamping piece (pos. 2) over suction hose piece.
Attach connection piece (pos. 3) until stop motion.
n
n
Put O-ring (pos. 4) in valve groove and screw down the union nut by hand.
n
Pull return hose piece through fixing hole (pos. 5) and attach it as suction hose piece.
n
Set suction lance into container.
CAUTION!
When connecting the suction and pressure pipes, ensure that the O-rings
(pos. 4) are fixed to the connectors so as to achieve the required seal.
NOTICE!
The use of an appropriate suction pipe from our product range is
recommended.
CAUTION!
When using other hose lines adjust the curved radius correspondingly.
The return hose must not be bent During the installation make sure that no the
return line is not on tension.
4
O-ring
5
Fixing hole