Microflow Plus / Metering Break - Ecolab EMP KKS E60 Manuel D'utilisation

Pompe deseuse à membrane
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Menu description
10.3.14.5 MicroFlow
PLUS
/ Metering break
When handling media with a tendency to emit gas, gas bubbles form in the system after
extended downtimes, resulting in corrupted volume values of the quantity to be metered
PLUS
and subsequently to the non-detection of the metering strokes by the MicroFlow
and
the issuance of an alarm.
PLUS
Fig. 68: Configuration / MicroFlow
- Metering break
"Metering break" is used to set the period without metering after which the monitoring
system is deactivated for a specific time
Ä Chapter 10.3.14.6 ' MicroFlow
(
PLUS
/ Metering delay' on page 92) to prevent the
undesired activation of the monitoring system.
Setting range: 2 - 3600s
Default setting = 240 sec.
91
417101442 Rev. 12-02.2019