Startup

9
Startup
Personnel:
CAUTION!
If the metering pipe can be shut off, an overflow valve (safety valve) should be
installed on the pressure side, which opens at the maximum permissible
pressure level, in order to protect the metering line.
This may prevent the metering pipe from bursting in the event of an operator
error.
Under unfavourable conditions, the pressure may rise to up to three times the
nominal pressure.
NOTICE!
After 24 hours or operation, the metering head screws are to be re-tightened
diagonally with a torque of approximately 3-4 Nm.
9.1

Key functions

Bild
9.2

Switching on/off the pump

Switching on = 2 Sec.
Switching off = 5 Sec.
n
Press START/STOP key (min. 2 sec.).
n
Press START/STOP key (min. 5 sec.).
417101442 Rev. 12-02.2019
n
Mechanic
n
Service personnel
n
Specialist
Bezeichnung Beschreibung
MENU/EXIT- function entry and exiting of the menu levels (keep keys
pressed down together
Menu/Exit
5 Modify set values upwards
6 Modify set values downwards
Start the pump
Stop the pump
Start/Stop
Confirmation key (ENTER) for set values
Test function
Test function (endurance test)
58