Configuration / Microflow Plus - Ecolab EMP KKS E60 Manuel D'utilisation

Pompe deseuse à membrane
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

10.3.14 Configuration / MicroFlow
Das MicroFlow
Durchflussmeßwertaufnehmer (Art. Nr. 288413, EBS Nr 10005481), einem
Anschlusskabel (Art. Nr. 284412, EBS Nr auf Anfrage) und einer Auswertebox
(Art. Nr. 248611, EBS Nr auf Anfrage).
The MicroFlow
measuring sensor (item no. 288413, EBS no. 10005481), a connecting cable
(item no. 284412, EBS no. on request) and an analysis box
(item no. 248611, EBS no. on request). Once the MicroFlow box
Ä Chapter 8.1 'Fitting the dongle box' on page 49) has been connected and this has
(
been activated by switching the pump off and then on again, "E60+microflow" appears on
the bottom left of the pump's display unit, and the Metering Monitoring option is
automatically replaced by the MicroFlow function with the appropriate sub-menu under
Configuration in the Pump menu.
If the pump software recognises that there is a MicroFlow box connected, and the
communication is then interrupted between the pump and the MicroFlow (through the
removal of the MicroFlow box, for example), an error message is displayed
Ä Chapter 12.2 'Alarm messages (display)' on page 113).To prevent this error message
(
appearing repeatedly, the communication (connection) must be restored, or the analysis
must be disabled in the pump software
(
Ä Chapter 12.2 'Alarm messages (display)' on page 113).
NOTICE!
When installing/commissioning the MicroFlow
please consult the operating instructions, item no. 417101314, EBS no. on
request.
The standard settings saved for "Strokes", "Deviation", "Metering break" and
"Metering delay" may only be viewed as defaults.
Depending on the design of the system (for instance, type of chemicals,
metering rate, cross-sections, line lengths...), the sensitivity of the MicroFlow
system must be adapted individually to the local conditions by modifying the
parameters mentioned above.
PLUS
PLUS
ist ein System zur Dosierüberwachung. Es besteht aus einem
PLUS
is a system for monitoring the dosing rate. It consists of a flow rate
PLUS
metering monitoring system,
87
Menu description
417101442 Rev. 12-02.2019

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Emp kks e60+

Table des Matières