10.4.2.2 Calibration / Start
Fig. 79: Kalibrierung /Starten
The pump runs 122 strokes (ca. 1 min).
The strokes are counted down from 122 to 0.
After the running process, the amount removed from the measuring cylinder
Ä Chapter 10.4.2.1 'Preparation' on page 100) must be read off. This quantity is then
(
entered as the calibration value (in ml or l).
NOTICE!
By activating the 'Menu/Exit' function, the running calibration can be
interrupted.
10.4.3
Calibration pump with oval gear meter (OGM
If a dongle box and an oval gear meter are connected and the "oval gear meter" function
Ä Chapter 10.3.11 'Configuration / Oval gear meter (only E60
(
on page 80) is activated, the oval gear meter pulse rate recorded is automatically
displayed at the end of the calibration process.
This is offset against the specified calibration value. A correlation thus occurs between the
oval gear meter pulses and the metered quantity.
PLUS
)
101
Menu description
PLUS
PLUS
& OGM
)'
417101442 Rev. 12-02.2019