Assembling; Pump Model Without Integrated Solenoid Valve; Pump Model With Integrated Solenoid Valve - Ecolab PDP II Notice Technique

Pompe doseuse pneumatique
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

5.

Assembling

5.1

Pump model without integrated solenoid valve

The compressed air must be switched on and off via an (external) 3/2 way compressed-air
solenoid valve provided by the customer.
Fig. 5.1
5.2

Pump model with integrated solenoid valve

Fig. 5.2
417101420_pneum_II.doc
Pos.
Description
1
Pump head
2
Pressure valve
3
Tube connection / pressure side
4
Diaphragm
5
Return Spring
6
Piston
Pressure connection
7
(for tube da 6 mm)
8
Valve block
9
Venting lever
10
Manual push button
11
Stroke adjustment
12
Diaphragm breakage outlet
13
Return line connection
14
Tube connection / suction side
15
Suction valve
This metering pump is
controlled via an integrated
3/2-way solenoid control
valve (pos. 1).
The compressed air inlet
(pos. 2) is located at the
control block.
Pos.
Description
1
Compressed-air
solenoid valve
2
Compressed air inlet
- 32 -