Disassembly; Installation - Ecolab Elados EMP IV E60 Notice Technique

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

11.4.1

Disassembly

 Open the terminal box (pos. 2) of the motor (pos. 1).
 Branch off the mains connection cable in the terminal box
 Loosen cable connections (pos. 3) and carefully pull out the cable
 The 4 motor attaching screws (pos. 4) have to be loosened crosswise and unscrewed.
 Pull off motor towards the top. In case of stiffness, two screw drivers, which are carefully
pulled into the water drip grooves (pos. 4) of the housing flange, can be used so that the
motor can be raised straight upwards. The motor should not be set on its edges.
11.4.2

Installation

 Clean splined shaft and housing flange, and moisten motor and splined shaft with
Teflon fat.
 Place motor shaft right onto splined shaft and pull softly until flange is reached. Do not
set motor on its edges.
 Turn the motor in a way that the terminal box points straight forward into the direction of
the stroke adjustment knob.
 Place attachment screws (pos. 4) and tighten them crosswise (tightening torque 12 Nm).
 Mains connection cable and (if necessary) connection cable to the pump housing may
then be reconnected
 Re-establish mains voltage supply.
CAUTION
After 24 hours attaching screws have to be tightened up by 12 Nm.
417101799_EMP_IV_E60.docx
- 111 -
Rev. 9-06.11

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Elados emp iv e60plus

Table des Matières