Control board diagram

After the lower part of the front has been removed (pos. 6), the terminal box becomes
accessible for drive and output signals. The PCB (pos. 9) may be slightly pulled out from the
pump housing together with the connection terminals (pos. 2, 3,
be detached.
The plug (pos. 4) at the front, which is already connected to the internal terminal, is used for
the connection of a suction pipe. If no suction pipe is used, the cover cap (pos. 5) enclosed
with delivery has to be attached together with the integrated bridges.
Use the selector switch (pos. 10) to change the function of the error or empty signal relay
contact from normally closed contact to normally open contact (see imprint on PCB).
417101799_EMP_IV_E60.docx
Pos.
Description
Fig. 7.15
1
Switch (without function!)
2
Connection terminals (X2)
3
Connection terminals (X1)
4
Suction pipe connection
5
Cover cap
6
Front panel
7
Connection for "On/Off" switch
8
Connection terminals (X3)
9
PCB
Selector switch for empty signal contact
10
(normaly open/normaly closed) of empty or fault
report relay.
11
Installed Dongle-Plate E60