10.3.12 Configuration / Metering controller (only
Fig. 10.28 Configuration / Metering controller (only E60
If an
OGM
Plus
quantity measured by the OGM is compared with a pre-defined dosage quantity target
value. If there is a discrepancy between the values, the metering frequency of the pump is
automatically increased or decreased.
Since metering frequency can only be adjusted within the performance limitations of the
pump, setting the dosage quantities higher than 80 or 90% of the maximum possible
metering frequency is not recommended. This will ensure that the metering controller retains
sufficient reserves to react to negative control deviations.
The metering controller function can only be used in the 'internal' and 'current' operating
modes. If the operating mode 'pulse' is selected, the metering controller function will not
work.
The metering controller function can only be activated if the pump is upgraded with a
dongle box
NOTE
connected.
To activate the Dongle-Box in connection with the oval gear meter, the power supply has
to be switched off and on again!
10.3.12.1
Selecting
417101441_EMP_III_E60.docx
PLUS
& OGM
is connected, when the metering controller function is activated, the dosage
to the
E60
PLUS
E60
&
OGM
PLUS
PLUS
)
and oval gear meter , type OGM
- 109 -
Fig. 10.27 Configuration / Oval gear meter
PLUS
(only E60
& OGM bzw. OGM
-
oval gear meter is inactive.
(Default setting)
oval gear meter is active.
)
PLUS
(see Accessories) is
PLUS
Fig. 10.29 Configuration / Metering controller: Selecting
-
controller function is inactive.
(Default setting)
controller function is active.
PLUS
): Selecting