Technical Specifications; Pump Keys; Pump Key 1 - Ecolab Elados EMP III E60 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

14

Technical Specifications

14.1

Pump keys

14.1.1

Pump key 1

E 6 0 0 0 0 2 5 P P
1 0 F P K E P P 9 9
Other specifications provided on request!
417101441_EMP_III_E60.docx
1. Electrical version
E 60
=
2. Pump output 50 Hz
00160
=
00250
=
00540
=
00800
=
01200
=
spezial version: high pressure
00160
= 1.6 MPa (16 bars) = 14,7 l/h (21,2 l/h)
00250
= 1.2 MPa (12 bars) = 23,5 l/h (28,2 l/h)
3. Pump head material
PP = PP
PV = PVDF
VA = V4A
4. Metering backpressure (not freely selectable)
03
= 0.3 MPa (3 bars) (for 120 l/h)
04
= 0.4 MPa (4 bars) (for 80 l/h)
10
= 1 MPa (10 bars)
special version: high pressure
16
= 1.6 MPa (16 bars)
12
= 1.2 MPa (12 bars)
5. Gasket material
FP
= Viton B
EP = EPDM
KA = Kalrez
6. Ball material
KE = ceramics
VA = stainlesssteel
PT
= Teflon
7. Valve material
PP = PP
PV = PVDF
VA = V4A
8. Valve spring
08
= suction valve without spring; pressure valve
double spring loaded (each 0.02 MPa)
10
= suction valve without spring; pressure valve
spring loaded (0.01 MPa)
99
= without spring
9. Mains power supply
01
= mains power cable 2 m
02
= 3-core m. power cable 2.4 m cable end sleeves
99
= without mains power cable
10. Voltage/frequency
01
= 115V / 50 Hz
02
= 115V / 60 Hz
03
= 230V / 50 Hz
9 9
0 3
04
= 230V / 60 Hz
10
= 3PE 400/230 V 50/60 Hz (only version E00)
- 127 -
(for explanation, see chapter 14.1.3)
16 l/h
25 l/h
54 l/h
80 l/h
120 l/h
(60 Hz)
(19 l/h)
(30 l/h)
(64 l/h)
(96 l/h)
(144 l/h)
(standard)
(0.25 MPa)
(0.32 Mpa)
(0.8 MPa)
(1.28 MPa)
(0.96 MPa)
(standard)
(standard)
(standard)
(standard)
(standard)
(standard)
Rev. 13-10.19

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Elados emp iii e60 plus

Table des Matières