Operating faults

12.1

Metering warning messages (display)

Display
reserve report
(flashing)
Fig. 12.1 Operating faults: Metering warning messages (display): reserve report
empty report
Fig. 12.2 Operating faults: Metering warning messages (display):empty report
metering lock
(only possible if this is
configured)
Fig. 12.3 Operating faults: Metering warning messages (display):metering lock
Indicator in operation
mode 4..20mA flashes
standard signal
monitoring responds
Fig. 12.4 Operating faults: Metering warning messages (display):indicator in operation mode
standard signal is above
--.-
23.0 mA
Fig. 12.5 Operating faults: Metering warning messages (display):standard signal
12.2

Alarm messages (display)

NOTE
Display
417101441_EMP_III_E60.docx
Meaning
pump continues
running
pump is stopped
pump is stopped
pump is stopped
pump runs in
continuous
operation
Appearing alarm messages can be quit by pressing the Start/Stop button.
Meaning
Motor is running
uncontrolled in
over dosage
continuous operation
Fig. 12.6 Operating faults: Alarm messages (display) failure 1
Motor is not running
despite of rotating
no metering
dosing symbol.
Fig. 12.7
Operating faults:Alarm messages (display) failure 2
motor in continuous
continuous
operation without
metering
request
Fig. 12.8
Operating faults:Alarm messages (display) failure 3
error in evaluating the
pump meters
metering monitoring or
too little or too
oval gear meter
much
Fig. 12.9
Operating faults:Alarm messages (display) failure 4
A dongle box which was
connected previously is
Pump is being
not detected the next
stopped
time the pump is
switched on
Fig. 12.10 Operating faults:Alarm messages (display) failure 9
An OGM
Plus
which was
connected previously
Pump is being
is not detected the
stopped
next time the pump is
switched on
Fig. 12.11 Operating faults:Alarm messages (display) failure 10
Pump is being
No comunication
stopped
between DongleBox
Box and pump
Fig. 12.12 Operating faults:Alarm messages (display) failure 12
Effect
Cause
low-level advance warning
active
empty report active
no external enable of the
pump
standard signal is under
3mA or cable to standard
signal connection is broken
standard signal exceeds the
display range
Effect
Cause
power electronic failure
backpressure too high
valve closed at pressure
side
Motor overheated/damaged
power electronic failure
optical sensor polluted
PC-board fault
Plug connection from gear to
PC-Board interrupted
tube fault
diaphragm fault
backpressure too high or too
low
Connection between
DongleBox and pump
interrupted
Connection between OGM
PLUS and DongleBox
interrupted
Transmission of data from
the dongle box to the pump
has been disrupted during
operation
- 122 -
Remedy
Refill the metering medium
Refill the metering medium
Activate external enable or
deactivate the metering lock in
the configuration menu.
(see chapter 10.3.7)
check the standard signal or
cable
reduce the standard signal
Remedy
replace PC-Board
reduce pressure
open valve
cool of the motor, or change
replace PC-board
send in pump
control optical sensor
connection
check the tubes
check the diaphragm
check the backpressure
Restore the connection
between the pump and the
dongle box, or disable the
dongle box in the software
(see chapter 12.2.1)
Restore the connection
between the dongle box and
OGM
Plus
, or disable the dongle
box in the software
(see chapter 12.2.1)
Check the connection between
the pump and the dongle box,
and replace the dongle box if
necessary