Maintenance; Replacing The Suction / Pressure Valve; Inserting The Metering Valves In The Correct Positions - Ecolab Elados EMP III E60 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

11

Maintenance

CAUTION
Electronics repairs must only be performed by trained electricians, following the safety regulations
of the professional association VB G 4 and ZH 1/11)!
CAUTION
Before calibration, maintenance, repairs or replacement of parts, the device must be disconnected
from all voltage sources if it is necessary to open up the device.
NOTE
The following inspections are recommended:
 suction pipes and pressure pipes for leak-free connections
 suction valve and pressure valve (chapter
and metering cartridges"), for dirt and tightness.
 discharge connection (chapter
 correct metering
 metering head screws (chapter
Fig. 11.3, Pos. 1) (stable seat, 3 - 4 Nm)
NOTE
11.1

Replacing the suction / pressure valve

11.1.1

Inserting the metering valves in the correct positions

Fig. 11.3 Inserting the metering valves in the correct positions
417101441_EMP_III_E60.docx
Prior to repair and maintenance work and metering of dangerous media, always rinse the
metering head, relieve the pressure pipe and wear protective clothing (protective goggles,
gloves and apron).
When opening the covers or removing parts, except when this is possible without tools,
voltage-carrying parts may be exposed. Connection points may also be under live voltages.
The maintenance interval is half-yearly. Shorter intervals are recommended in the event of
heavy loads (e.g. continuous use).
5.1
11.2
The life of the diaphragm depends on the backpressure, operating temperature and
metering medium.It is recommended to inspect the diaphragm more frequently in extreme
operating conditions or if abrasive substances are metered.
Type: 00160 - 00540
Pos. Description
CONNECTION SET
1
Union nut
A
2
Clamping piece
3
Tapered part
PRESSURE VALVE
4
O-Ring, Ø 12 x 2,5
B
5
Pressure valve
6
O-Ring, Ø 18 x 2,5
7
O-Ring, Ø 16 x 2,5
8
O-Ring, Ø 7,65 x 1,78
SUCTION VALVE
C
4
O-Ring, Ø 12 x 2,5
5
Suction valve
6
O-Ring, Ø 18 x 2,5
7
O-Ring, Ø 16 x 2,5
Fig. 11.2 Replacing the suction / pressure valve,
type 00160 - 00540
On the suction valves and flow valves, the flow direction is marked with
an engraved arrow.
When inserting it, always ensure that the valves are inserted according
to the flow direction!
11.1
"Replacing the suction / pressure valve
"EMPII E60" on the pump head (diaphragm breakage).
"Replacing the diaphragm and pump head",
- 120 -
Type: 00800 - 01200
Pos. Description
CONNECTION SET
1
Union nut
A
2
Clamping piece
3
Tapered part
SUCTION-/PRESSURE
VALVE
B
4
O-Ring, Ø 28 x 3,5
Suction-/Pressure
5
valve
Fig. 11.1 Replacing the suction / pressure
valve, type 00800 - 01200
Rev. 13-10.19

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Elados emp iii e60 plus

Table des Matières