10.3.11.1 Selecting

10.3.12 Configuration / Metering controller (only
Fig. 10.28 Configuration / Metering controller (only E60
If an
OGM
PLUS
quantity measured by the OGM is compared with a pre-defined dosage quantity target value.
If there is a discrepancy between the values, the metering frequency of the pump is
automatically increased or decreased. Since metering frequency can only be adjusted within
the performance limitations of the pump, setting the dosage quantities higher than 80 or 90%
of the maximum possible metering frequency is not recommended. This will ensure that the
metering controller retains sufficient reserves to react to negative control deviations.
The metering controller function can only be used in the 'internal' and 'current' operating
modes. If the operating mode 'pulse' is selected, the metering controller function will not work.
NOTE
10.3.12.1 Selecting
417101438_EMP_II_E60
PLUS
& OGM
is connected, when the metering controller function is activated, the dosage
The metering controller function can only be activated if the pump is upgraded with a
dongle box to the
E60
PLUS
connected. To activate the Dongle-Box in connection with the oval gear meter, the power
supply has to be switched off and on again!
E60
&
OGM
PLUS
PLUS
)
and oval gear meter , type
Fig. 10.29 Configuration / Metering controller: Selecting
-
- 110 -
Fig. 10.27 Configuration / Oval gear meter (only E60
PLUS
OGM bzw. OGM
): Selecting
-
oval gear meter is inactive.
(Default setting)
oval gear meter is active.
)
PLUS
OGM
(see Accessories) is
PLUS
controller function is inactive.
(Default setting)
controller function is active.
PLUS
&
Rev. 12-01.19