8

Upgrading the EMPII E60 to the EMPII E60

To upgrade the
obtain the
dongle box
The
dongle box
measuring the metering rate. If the
off and then on again, "E60+" appears on the bottom left of the pump's display unit. If an
OGM
(oval gear meter) is connected to slot V on the dongle box and is activated by
PLUS
switching the pump off and then on again, "E60++" appears on the pump's display unit, and
the oval gear meter function is automatically enabled under Configuration in the Pump menu.
In addition to the slot expansion, the
sensor to be analysed via conductivity measurements. When the
and is activated by switching the pump off and then on again, "E60+microflow" appears on
the bottom left of the pump's display unit, and the MicroFlow function is automatically enabled
in the appropriate sub-menu under Configuration in the Pump menu.
If the pump software recognises that there is a
connected, and the communication is then interrupted between the pump and the peripheral
unit (through the removal of the unit, for example), an error message is displayed
(see chapter
To prevent this error message appearing repeatedly, the communication (connection) must
be restored, or the analysis must be disabled in the pump software (see chapter
"Disabling a
The only outward difference between a
appropriate item number
Art. No. 248611, EBS No. on request)
8.1

Fitting of the Dongle Box respectively the MicroFlow-Box

Fig. 8.2
Fitting of the Dongle-Box or the MicroFlow-Box 1
417101438_EMP_II_E60
EMP II E60
to the
or the
MicroFlow
is a slot extension, as well as a means of connecting an oval gear meter for
12.2
"Alarm signals (Display)").
dongle box, OGM
PLUS
(dongle box
Pos.
Description
V
input for oval gear meter or MicroFlow transducer
Fixed connector cable for connecting the pulse input to the EMP pump
VI
(input II)
1
Connection lead for connection to input II of the pump
2
Dongle-box or MicroFlow-box
VII
input for batch pulse and metering lock
VIII
input for pulse, standard signal input (mA) and metering lock
Fig. 8.1
Fitting of the Dongle-Box respectively the MicroFlow-Box
EMP II E60
and thus access the additional functions,
PLUS
PLUS
from our range of accessories.
dongle box
is fitted and is activated by switching the pump
MicroFlow
enables a special flow rate monitoring
PLUS
dongle
box,
, MicroFlow
in the pump software").
PLUS
dongle box
and a
Art. No. 248606, EBS No. 10016094,
Fig. 8.3
Fitting of the Dongle-Box or the MicroFlow-Box 2
- 92 -
PLUS
MicroFlow box
OGM
or
MicroFlow box
PLUS
MicroFlow box
is a sticker with the
MicroFlow box
is connected
12.2.1
Rev. 12-01.19