Installing the suction pipe with low-level advance warning and empty report

Slot I must always be assigned, either through the mounted strapping plug (protective cap
with corresponding symbol; see chapter 7.2.1, Fig. 7.10, Pos. I) or through connection to
NOTE
the empty report device (suction lance plug). The setup of low level contact is invertible.
(see chapter
7.2.3
Connector assignment of slot II (5-terminal)
input for pulse signal, standard signal, metering lock, batch and metering monitoring
Fig. 7.12 slot II
(5-terminal)
 Remove the protective cap
 Mount the connector plug according to the connector assignment.
WARNING
Only use a connector plug from our product range! (included in the delivery scope)
7.2.3.1

Installing the pulse control (water meter)

Fig. 7.13 Installing the pulse control
(water meter)
417101438_EMP_II_E60
10.3.8
"Configuration Low level contact")
1
+
4
= Input low-level warning
low-level advanced warning open:
low-level advanced warning active (invertible circuit logic, see
chapter 10.3.8), empty report symbol on display flashes, pump is
not locked.
PIN
Assignment
1
Relay input
4
GND (┴)
3
+
4
= Input empty report
Switch contact empty report open:
empty report active (invertible circuit logic, see chapter 10.3.8),
empty report symbol on display appears, pump is locked.
PIN
Assignment
3
Relay input
4
GND (┴)
Fig. 7.11 Installing suction pipe with low-level advance earning and empty report
Conductor coloring
Pin
(cable connection)
1
brown
2
white
3
blue
4
black
5
grey
(plug assignments: see also chapter
terminal)")
2
PIN
1
PIN
Assignment
output 5 V, DC (loadable with max. 50 mA)
pulse input (also as configurable batch / metering monitoring;
see
10.3.13
& 10.3.15)
metering lock (also as configurable batch / metering
monitoring, see
10.3.13
GND (┴)
Input standard signal 0/4...20 mA
14.3.5.2
"Pin assignment / conductor coloring Connector II (5-
+
4
= Pulse input with potential-free contact
Assignment
2
Relay input
4
GND (┴)
+
2
+
4
= Pulse input with electronic switch (NPN)
Assignment
1
5 V, DC
2
Relay input
4
GND (┴)
The minimum pulse- or pause time is 15 ms.
- 87 -