Maintenance; Replacing The Suction / Pressure Valve And Metering Cartridges; Ball-Valve (V3), 1,4 - 2,5 L/H For Type: V3014 - V3025 - Ecolab Elados EMP II E60 Mode D'emploi

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

11

Maintenance

Prior to repair and maintenance work and metering of dangerous media, always rinse the
CAUTION
metering head, relieve the pressure pipe and wear protective clothing (protective goggles,
gloves and apron).
Electronics repairs must only be performed by trained electricians, following the safety regulations
of the professional association VB G 4 and ZH 1/11)!
When opening the covers or removing parts, except when this is possible without tools,
CAUTION
voltage-carrying parts may be exposed. Connection points may also be under live
voltages.
Before calibration, maintenance, repairs or replacement of parts, the device must be disconnected
from all voltage sources if it is necessary to open up the device.
The maintenance interval is half-yearly. Shorter intervals are recommended in the event of
NOTE
heavy loads (e.g. continuous use).
The following inspections are recommended:
 suction pipes and pressure pipes for leak-free connections
 suction valve and pressure valve (chapter
and metering cartridges") for dirt and tightness.
 discharge connection (chapter
breakage).
 correct metering
 metering head screws (chapter
(stable seat, 3 - 4 Nm)
The life of the diaphragm depends on the:backpressure, operating temperature and
NOTE
metering medium.It is recommended to inspect the diaphragm more frequently in extreme
operating conditions or if abrasive substances are metered.
11.1

Replacing the suction / pressure valve and metering cartridges

 Disassemble the suction valve and pressure valve with a crescent wrench (SW 22).
 Assemble all the O-rings.
 Assemble the metering cartridges (on valve version V3).
 Screw in the suction valve and pressure valve in the correct position (torque of 2-3 Nm)
11.1.1
3 Ball-Valve (V3), 1,4 – 2,5 l/h for type: V3014 - V3025
417101438_EMP_II_E60
11.1
5.1
"EMPII E60") on the pump head (for diaphragm
11.2
"Replacing the diaphragm and pump head")
Pos. Designation
CONNECTION SET
1
Union nut
A
2
Clamping piece
3
Tapered part
SUCTION-/PRESSURE VALVE
4
O-Ring, Ø 10 x 2,5
B
5
Suction-/ Pressure valve
6
O-Ring, Ø 14 x 2,5
METERING CARTRIDGE V3
7
O-Ring, Ø 7 x 1,5
C
8
Metering cartridges
9
O-Ring, Ø 2,5 x 1,5
Fig. 11.1 Maintenance: 3 Ball Valve (V3), 1,4 – 2,5l/h for type: V3014 – V33025
- 125 -
"Replacing the suction / pressure valve
Rev. 12-01.19

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Elados emp ii e60plus

Table des Matières