Vci Manager Software On The Pc Unable To - Bosch MTS 6517 VCI Notice Originale

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 36
8.4
VCI Manager Software on the PC Un-
able to Communicate with the VCI
VCI Manager software must be installed on the PC, and
the VCI must be powered up before it will communicate
using USB. The VCI must also be configured for wireless
communication before it will communicate with your
wireless network. The VCI connects first using USB, if
available; if USB is not available, the VCI connects using
wireless.
Recommendations:
R
Check that the cables are securely attached to the
VCI, the VCI has completed its power up sequence,
the connector pins are clean, and the VCI Manager
software is running.
R
If connecting using USB, check that the VCI USB
connection is detected by Windows:
$
Connect the VCI to the PC USB port, then power
up the VCI.
$
From the Windows Control Panel, open the Net-
work and Dial-up Connections window.
$
Check for device name "RNDIS/Ethernet Gadget".
If not running, then either the USB driver has not
been loaded on the PC or the VCI is not powered
and connected to the USB. Check all USB ports
on the PC and verify that the VCI is powered on.
R
Contact your IT department for the correct VCI set-
tings.
R
If the VCI Manager is still not able to communicate
with the VCI, perform the Recovery Procedure.
Robert Bosch GmbH
1. VCI Manager will connect to VCI via USB
2. VCI Manager will connect to VCI via Ethernet
3. VCI Manager wil connect to VCI via Wireless
4. Wireless Point-to-Point is not setup. Connect VCI to
PC using USB cable to complete setup
5. Wireless Adapter in the PC and in the VCI are incom-
patible with each other.
6. VCI Manager is connected to the VCI
8.5
VCI Turns Off Immediately When Dis-
connected from the Vehicle
The VCI should stay on for a factory set time if power is
lost during engine cranking or after it is disconnected from
power (vehicle DLC or AC/DC 12-volt power adapter).
Recommendations:
R
Power up the VCI and verify that it has the same
problem when power is removed.
| MTS 6517 VCI | 33
en
|
1699200092 B
2017-06-20

Publicité

Table des Matières
loading

Table des Matières