During commissioning
During operation
During cleaning
Disposal
AVENTICS
Only use pre-assembled and tested cables. This will rule out
the possibility of a reverse polarization.
– The device corresponds to the restrictions in the IP 65
protection class. Before commissioning, make sure that all the
connection seals and plugs are leakproof to prevent fluids and
foreign bodies from penetrating the device or plug connections.
The electronics can be damaged by water penetration. Never
open the cap on the calibration port. Ensure that the four
screws have been tightened with the correct torque. Never
loosen the two screws on the device cover.
Other system parts may be damaged by uncontrolled device
movements if it has not been properly mounted. Make sure
that the device is attached to a base plate that is securely
fastened to the machine or a mounting plate.
Touching the valve coils during operation may lead to burns.
Let the device cool off before disassembling. Do not touch the
device during operation.
If the housing ventilation port is closed, there is no
atmospheric compensation and the characteristics curve will
change. Ensure that the air can circulate freely through the
housing ventilation port. Never operate the device in an
atmosphere containing oil.
Never use solvents or aggressive detergents. Only clean the
device using a slightly damp cloth. Only use water to do this
and, if necessary, a mild detergent.
Dispose of the device in accordance with the currently
applicable regulations in your country.
| ED07 | R41400766–BDL–001–AB
47
For your safety