3.7 ATTACHING THE REMOTE CABLE
1. Put on the cable housing (2) and the cable adjuster (1).
→ Only cable housings with an outer diameter of 4 mm must be used.
→ Before and after the cable adjuster there must be at least one short piece of cable housing.
→ Screw in the cable adjuster completely and then loosen one turn.
2. Switch the remote lever to position "OPEN" and insert the cable through the cable housing (2).
3. Unscrew the clamping screw (3) on the remote wheel.
4. Guide the cable through the cable stop and place it around the remote wheel (4).
5. Pull the cable tight, clamp it with the clamping screw and tighten it with a max. torque of 1.3 Nm.
6. Operate the remote lever several times.
7. Adjust the cable tension with the cable adjuster (1).
→ The remote lever locks in position "LOCK" and activates the lockout.
→ In the "LOCK" position, the remote wheel touches the stop of the cable guide.
8. Shorten the cable to the desired length and attach a cable end crimp.