Electrical Analysis; Inspection; Digital Circuit Tester; Peak Voltage Measurement - SELVA MARINE Goldfish 4 Manuel D'entretien

Table des Matières

Publicité

ELEC

ELECTRICAL ANALYSIS

ELECTRICAL ANALYSIS

INSPECTION

Digital circuit tester

NOTE:
Throughout this chapter the digital circuit
tester's part number has been omitted.
Refer to the following part number.
Digital circuit tester:
90890-06752
NOTE:
"1 — 1" indicates a continuity of electrici-
ty; i.e., a closed circuit at the respective
switch position.

Peak voltage measurement

NOTE:
When checking the condition of the igni-
9
tion system it is vital to know the peak
voltage.
9
Cranking speed is dependant on many
factors (e.g., fouled or weak spark plugs,
a weak battery, etc.). If one of these is
defected, the peak voltage will be lower
than specification.
9
If the peak voltage measurement is not
within specification the engine will not
operate properly.
9
A low peak voltage will also cause com-
ponents to prematurely wear.

Peak voltage adaptor

NOTE:
9
Throughout this chapter the peak voltage
adaptor's part number has been omitted.
Refer to the following part number.
9
The peak voltage adaptor should be used
with the digital circuit tester.
Peak voltage adaptor:
90890-03169