Setting The Diagnostic Messages - Aventics PROFINET-IO Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 117
92
AVENTICS | PROFINET-IO | R412015162–BDL–001–AE
Commissioning and Operation
Table 19:
S3, defining the monitoring threshold for valve voltage
Bit
8
7
3.1
3.2
3.3
3.4
3.5
3.6
3.7
OFF
ON
3.8
OFF
ON
6.1.2
The S3 mode switch used to set the diagnostic messages is
located under the PG fitting A (see Fig. 6 and Fig. 7 on page 88).
When delivered, the diagnosis is deactivated (S3.1 – 3.6 set
to OFF)
O
Activate or deactivate the diagnostic message to the
IO controller with switches S3.1 – 3.6.
The modified switch position will only be activated after
a new "power on".
The queued diagnoses are shown on the LEDs of the
BDC-B-DCP_32 even if the diagnostic message on the
IO controller is turned off!
6
5
4
3
OFF
ON
OFF
ON
OFF
ON
OFF
ON

Setting the diagnostic messages

2
1
OFF Valve driver diagnosis switched off
ON
Valve driver diagnosis switched on
OFF
Low voltage message U
ON
Low voltage message U
Low voltage message U
Low voltage message U
Message U
Message U
Message U
Message U
SREG short circuit message off
SREG short circuit message active
U
tolerance - 15%
Q1
U
tolerance - 10%
Q1
U
tolerance - 15%
Q2
U
tolerance - 10%
Q2
Meaning
switched off
Q1
active
Q1
switched off
Q2
active
Q2
missing switched off
Q1
missing active
Q1
missing switched off
Q2
missing active
Q2

Publicité

Table des Matières
loading

Table des Matières