Chapter 3 Installation of the OTU-8000
OTU-8000 and WEB Interface

Configuring the OSU-9600

48
If the configuration the OTU-8000 registered do not match
configuration the one detected, the differences are displayed in red.
Click on the button
registered configuration with the detected one.
On the configuration menu, click on the OSU/OSX Setup tab. The
following page displays
Fig. 55
OSU Settings
The OSUs can be configured differently:
– either all the OSUs are in cascade mode
– or one OSU is set as distributor and the other are in cascade.
OSUs in cascade mode
1 Disconnect all the OSU that can be connected to the OTU before
performing the configuration.
2 Plug the OSU with address 1 via the RS485 to the OTU-8000.
3 Enter the OSU Address 1 for the first OSU plugged, (2 if it is the
second one, 3 for the third one etc.)
The addresses must be consecutive! (1, 2, 3, 4...).
4 Click on A
PPLY
5 Once completed, a green text confirm the address has been
successfully applied.
Confirmation of
the OSU address
modification
Fig. 56
OSU address successfully changed
6 Unplug the OSU and connect the second OSU, which will be config-
ured with address 2, to the OTU-8000.
7 Redo
step 3
1.This can happen if you replace or remove an OTDR plug-in for example
User Manual
Apply Detected Module
to
6
for all the OSUs to be configured.
7OTU80010/06
1
with the
then
OK
to match the