Chapter 3 Installation of the OTU-8000
OTU-8000 and WEB Interface
52
Fig. 63
Scan results
NOTE
If the number of OSX8000 detected is false, this may be due to a bad
configuration of the addresses (example: two OSX8000 have the
same address).
To ensure that all OSX8000 connected are configured with the good
address:
a Enter the address of one OSX8000 in the External Switch
Address box
b Click on Blink the OSX
The LED Addr. of the OSX8000 with this address blinks in green for
20 seconds.
8 Click on the Switch tab to apply the configuration (see
the optical switch" on page
OSX8000 configuration with one OSX8000 as multiplexer
This configuration is to be done when no OTAU is set into the OTU-
8000.
1 Connect the first OSX8000, which will be used as multiplexer for the
others, to the OTU-8000 with the command cable.
1 OSX8000 as distributor
Address 2
Address 1
Address 31
Fig. 64
Connection OTU-8000 <-> OSX8000 <-> OSX8000
2 Connect all the others OSX8000 (see
3 Press Settings button onto the OSX8000 multiplexer front panel.
The LED Addr. turns on, in solid green.
4 Enter the address 31 for the OSX8000 multiplexer.
User Manual
7OTU80010/06
58).
Command cable OSX <-> OSX
(Kit E98OSXXOSX)
Command cable OTU <-> OSX
(Kit E98OTUXOSX)
Figure 60 on page