Chapter 1 Prerequisites and delivery of the OTU-8000
Prerequisites of the OTU-8000
Height
The OTU-8000 occupies 2 rack units of space (2U). However,
according to the modules added to the equipment, the height can be
increased:
– + 1 OSU9600 module = + 4U
– + 2 OSU9600 module = + 8U
– + 1 OSX8000 module = 1U
– + 1 Launch Fiber Module = + 1U
OSX8000 Module
Launch Fiber Module
1U
1U
2U
2U
OSU-9600 Module
4U
2U
Fig. 5
Rack space with hardware extensions
OTU-8000 Power Supply
OTU-8000 Consumption
Your local electrical installation must comply with the OTU-8000 power
consumption:
– DC Input: -36 to -60V
– Power consumption: 30W
Section of electric wires
Electric wires plugging into the OTU-8000 must have a section inferior
or equal to 1,5mm².
AC Power supply
The OTU-8000 works on -48V DC power. The OTU-8000 can be deliv-
ered with the specific AC to DC converter, if ordered as an option (Ref:
E98ACDCxx).
User Manual
7OTU80010/06
5