Testing and measuring a fiber
under alarm

Testing a fiber

Measuring a fiber

Displaying alarm details

Uncheck Unit, Tested Fiber and/or Com in the filters area if you wish to
filter alarms according to their type.
Select the minimum level of severity
alarms according to their severity level.
You may see at all times which filter you applied by looking at the filters
area.
Major has been selected:
Only major and critical alarms will be
displayed (they appear in darker blue).
Tested Fiber has been unchecked:
Only unit and communication alarms will
be displayed.
Fig. 83
Filters area
1 Select in the alarm monitor page, the link under alarm on which you
wish to request a test.
2 Click on the tab Test and check Test.
3 Click on Submit.
The list of all saved OTDR tests is displayed.
4 Select one and click on
5 Once the test / measurement is completed, the trace is displayed.
1 Select in the alarm monitor page, the link under alarm on which you
wish to request a measurement.
2 Click on the tab Test and check Measurement.
3 Click on Submit.
The OTDR measurement configuration is displayed.
4 Click on
Start
to perform the measurement.
5 Once the measurement is completed, the trace is displayed.
1 In the Alarm Monitor page, select the alarm for which you want to
see a general description.
2 Go to the Alarm Detail page.
1.All alarms with a equal or higher severity level are displayed. For example: if Major is clicked,
both major and critical alarms are displayed.