Chapter 3 Installation of the OTU-8000
OSU-9600 additional hardware
Higher configurations with
one OTDR

Configuration with 2 OSU

38
OTAU (Internal schematic
view from above)
Optical switch module
1
C2
C1
OTDR (2)
OTDR (1)
Fig. 39
Configuration 2x36 and 2x48
The OSU-9600 comes in addition to the OTAU plug-in.
1 Connect your OTDR to C1 on the OTAU.
2 Connect C2 from the OTAU to Common from the OSU-9600.
NOTE
Any testing port can be used to connect to the OSU-9600, neverthe-
less, it is recommended to use 1 for clarification of the configuration.
3 Connect all fibers to be tested from the ODF to each testing port on
the OTAU and each testing port of the OSU-9600.
OTAU (Internal schematic
view from above)
Optical switch module
Ports 1, 2
C2
C1
OTDR (1)
Fig. 40
Internal schematic view (from above) of a 2 to 72 optical
switch with a OSU-9600 addition
Two OSU-9600 are added to the optical switch.
1 Connect C1 from the first OSU-9600 to port 1 of the optical switch.
2 Connect C1 from the second OSU-9600 to port 2 of the optical
switch.
3 Connect all fibers to be tested from the ODF to each testing port on
the OTAU and each testing port of the OSU-9600.
User Manual
7OTU80010/06
OSU-9600 (Internal schematic
view from above)
Optical Switch Module
Common
OSU-9600 (Internal schematic
view from above)
Optical Switch Module
...
Common
ODF
Ports 1, 2
...
Connections
to do
ODF
Ports 1, 2
...
Connections
to do

Publicité